FAQ Coolers
| PROBLEM | CAUSE |
| 1. The machine does not run. | 1.1.-Mains connection is not correct.
1.2.-No current at the connection plug. 1.3.-Defective power cable. 1.4.-General switch is broken. 1.5.-Defective faston connectors for the general switch. |
| 2. The mixer does not function. | 2.1.-Defective motor connection.
2.2.-Defective mixer switch. 2.3.-Paddle motor or paddles blocked. 2.4.-Defective motor reducer. |
| 3. Cold pilot light does not light even when turning on the right switch. | 3.1.-Switch for this mixer is disconnected.
3.2.-Pilot light is burned out. 3.3.-Electronic thermostat defective or disconnected. 3.4.-Electronic thermostat transformer defective or disconnected. |
| 4. Compressor does not start:
4.1 There is no current.
4.2 There is current.
|
4.1.1.-Electronic thermostat transformer defective or disconnected. 4.1.2.-Electronic thermostat defective or disconnected. 4.2.2.-Starter relay. 4.2.3.-Breaker for overheating. 4.2.4.-Compressor. |
| 5. Machine does not cool at all. | 5.1.-Coolant gas leak.
5.2.-Dirty condenser. 5.3.-Insufficient ventilation around the machine. 5.4.-Broken fan motor. 5.5.-Electronic thermostat defective or disconnected. 5.6.-Cold switch is defective or on Setting zero. |
|
6. Tap leaks. |
6.1.-Rubber tube defective or not properly fitted.
6.2.-Check tap springs. |
|
7. Tank leaks. |
7.1.-Defective tank seal. |